Karlsruhe Astrophysical Database of Nucleosynthesis in Stars
s-process
[Standards]   [Logbook]   [FAQ]   [Links]   [Contact]
p-process
Available isotopes for Selenium (Z=34)
  74Se   75Se   76Se   77Se   78Se   79Se   80Se   82Se
Go to isotope
Recommended MACS30 (Maxwellian Averaged Cross Section @ 30keV)
80Se 81Se




Cross sections do not include stellar enhancement factors!
History
VersionTotal MACS [mb]Partial to gs [mb]Partial to isomer [mb]
1.039.8 ± 4.1-8.6 ± 0.9
0.042 ± 3--

(Version 0.0 corresponds to Bao et al.)
Comment
New rec. value and MACS vs. kT table is average from recent evaluations (tendl15,endfb71,jendl40) which fits measurement of IKK11. Uncertainty is 4.7% from IKK11 plus deviation between the evaluations. No values shown for Se-80 in the paper, only available as private communication to EXFOR. There is reasonable agreement with the older data of WBK86b. Isomeric ratio at kT= 30 keV is IR= 0.217.
Last review: June 2016
List of all available values
originalrenorm.yeartypeCommentRef
34.8-11.5
E(n)= 21-542 keV
2010cPelletron, TOF, Au:ENDF/B-VI and MaG67bIKK11
44 ± 3
44.91986cVdG, TOF, Au:B-V norm. by 613/602=1.02WBK86b
42.3
2015eTENDL-2015 using the TALYS codetendl15
39.5
2014eJEFF-3.2 using calculations from TENDL-2012jeff32
39.4
2011eENDF/B-VII.1endfb71
38.0
2011eJENDL-4.0jendl40
67.2
2004eJEFF-3.1jeff31
39.4
2002eJENDL-3.3jendl33
50.7
2005tMOST 2005Gor05
55.9
2002tMOST 2002Gor02
38.2
2000tNON-SMOKERRaT99
20 ± 12
1971eAGM71
34
1981tHar81
41
1978tWFH78
Partial cross section to 81mSe:
9.1
25 keV
8.6 ± 0.92013uVdG, Act., Au:RaK88 corrected by 632/586= 1.0785; energy dep. from jendl40; unpublishedID13b


Original:MACS [<σ v>/vT] (mb) for kT=30 keV, based on the published cross sections except where indicated otherwise.
Renorm:MACS [<σ v>/vT] (mb) for kT=30 keV for which the reference or standard cross section was meanwhile improved.
Type: The letters and numbers in the column labelled 'type' give information on how the cross section has been obtained:
cDirectly quoted from the reference itself
eEvaluated value taken directly from the reference
tTheoretical value
uUnpublished value
MACS, SEF and Reaction Rates for different energies
Energy5keV8keV10keV15keV20keV25keV30keV40keV50keV60keV80keV100keV
MACS
173.8 ± 23.1
-
93.6 ± 6.8
65.7 ± 4.3
52.4 ± 3.7
44.8 ± 3.8
39.8 ± 4.1
33.8 ± 4.5
30.1 ± 4.6
27.7 ± 4.6
24.6 ± 4.4
22.7 ± 4.2
Xfactor1.001.001.001.001.001.001.001.001.001.001.000.99
SEF1.001.001.001.001.001.001.001.001.001.001.001.00
Rate
1.03
-
0.79
0.68
0.62
0.60
0.58
0.57
0.57
0.57
0.59
0.60

MACS:
Reference: tendl15,endfb71,jendl40
Procedure: 'e+t' (The MACS from kT=5 keV to 100 keV are derived from calculated cross sections, which are then normalized to experimental data, e.g. to the values at kT=25 keV obtained in activation measurements. In these cases the uncertainties should be linearly increased below 25 and above 30 keV to reach about 30% at the extreme kT values.)
Year: 2016

X-factor:
Reference: Rau12
Year: 2012

SEF (Stellar enhancement factor):
Reference: Rau09
Year: 2009
Comment:

Rate:
Reaction rate NA<σv> given in 107 cm3/mole/s, including SEF
Chart of nuclei
up
left
80Kr
2.28
267 mb
81Kr
229.02 ka
607 mb, β+
82Kr
11.58
90 mb
83Kr
11.49
243 mb
84Kr
57
38 mb
79Br
50.69
622 mb
80Br
17.68 m
β-
81Br
49.31
239 mb
82Br
1.47 d
β-
83Br
2.40 h
β-
78Se
23.77
109 mb
79Se
294.99 ka
263 mb, β-
80Se
49.61
42 mb
81Se
18.45 m
β-
82Se
8.73
9 mb
77As
1.62 d
β-
78As
1.51 h
β-
79As
9.01 m
β-
80As
15.20 s
β-
81As
33.30 s
β-
76Ge
7.83
21.5 mb
77Ge
11.30 h
β-
78Ge
1.47 h
β-
79Ge
18.98 s
β-
80Ge
29.50 s
β-
right
down
Style: (S, M, L, XL or Alberto)


Isotope: Selenium